REF. — TECHNICAL GLOSSARY 55 TERMS · A–Z
Engineering Reference

HV engineering glossary.

55 terms every substation and transmission project runs on — defined the way our engineers use them, from AIS to VT.

A
ACSR
Aluminum Conductor Steel Reinforced — the most common overhead line conductor: aluminum strands for conductivity around a steel core for mechanical strength.
AIS
Air-Insulated Switchgear — substation switchgear that uses ambient air as the insulating medium, with equipment mounted in an open outdoor yard.
Ampacity
The maximum current a conductor can carry continuously without exceeding its temperature rating.
Autotransformer
A transformer whose primary and secondary share part of the same winding — common at 400/230 kV interconnection points for its smaller size and cost.
B
Bay
A complete switching unit within a substation — typically a breaker with its disconnectors, instrument transformers and connections to the busbar.
BESS
Battery Energy Storage System — grid-connected batteries (commonly LFP lithium-ion) used for backup power, peak shaving and renewable integration.
Busbar
The rigid or strung conductor system that distributes current between bays inside a substation.
Bushing
The insulated feed-through that carries a conductor safely through the grounded tank wall of a transformer or breaker.
C
Capacitor Bank
A set of capacitors connected to the grid to supply reactive power, improve voltage profile and power factor.
Catenary
The natural sag curve a conductor forms between two towers under its own weight — central to clearance and tension design.
Circuit Breaker
A switching device that can interrupt fault current — SF6, vacuum or air-blast — and the protective heart of every bay.
Conservator
The expansion tank on top of an oil-filled transformer that accommodates oil volume changes with temperature.
Corona
Ionization of air at a conductor's surface under high electric field — causes losses, audible noise and radio interference; controlled by bundling.
Cross-arm
The horizontal member of a tower that carries the insulator strings and conductors.
CT
Current Transformer — an instrument transformer that scales primary current down to measurable levels for metering and protection relays.
CVT
Capacitor Voltage Transformer — measures high voltage via a capacitive divider; standard at 132 kV and above.
D
Dead-end Tower
A tension tower that anchors the full mechanical tension of the conductors — used at angles, crossings and line ends.
Dead-tank Breaker
A circuit breaker whose interrupting chamber sits inside a grounded tank, with CTs integrated on the bushings.
Disconnector
An off-load isolating switch that provides a visible break for safe maintenance — also called an isolator.
Double Circuit
A transmission line carrying two independent three-phase circuits on the same towers — six phase conductors total.
E
Earthing Switch
A grounding blade integrated with a disconnector that safely earths an isolated section before work begins.
EHV
Extra-High Voltage — transmission voltages of roughly 345 kV to 765 kV; 400 kV lines are EHV class.
EPC
Engineering, Procurement and Construction — a delivery model where one contractor designs, sources and builds the complete facility.
F
FACTS
Flexible AC Transmission Systems — power-electronic devices (SVC, STATCOM, TCSC) that control voltage and power flow dynamically.
Feeder
A circuit that carries power from a substation toward loads or between voltage levels — line feeders, transformer feeders.
G
Gantry
The steel portal structure at a substation that terminates incoming lines and supports the busbar.
GIS
Gas-Insulated Switchgear — switchgear enclosed in grounded metal housings filled with SF6, achieving a fraction of the AIS footprint.
Grid Code
The technical rules a facility must meet to connect to the transmission network — voltage ride-through, frequency response, protection.
H
Hot-dip Galvanizing
Immersing fabricated steel in molten zinc for corrosion protection — standard for towers and substation structures.
I
IEC 61850
The international standard for substation communication and automation — the backbone of modern digital substations.
Insulator String
A chain of disc insulators connecting an energized conductor to a grounded tower — length scales with voltage.
K
kV
Kilovolt — one thousand volts; the unit used to describe voltage classes such as 63 kV, 132 kV, 230 kV, 400 kV.
L
LFP
Lithium Iron Phosphate — the dominant battery chemistry for stationary storage, valued for thermal stability and cycle life.
Line Trap
A tuned inductor at a line's entry to a substation that blocks power-line-carrier communication signals from entering the bus.
M
Monopole
A single-shaft steel pole structure used where lattice tower footprints are impractical — common in urban lines and telecom.
O
OLTC
On-Load Tap Changer — the mechanism that adjusts a transformer's turns ratio under load to regulate voltage.
ONAN / ONAF
Transformer cooling classes — Oil Natural Air Natural / Oil Natural Air Forced (fans); most large units are dual-rated.
OPGW
Optical Ground Wire — a shield wire with optical fibers inside, providing lightning protection and communications on one cable.
P
PC
Procurement and Construction — a delivery model where the contractor sources and builds to a design the owner provides.
Power Factor
The ratio of real power to apparent power — corrected with capacitor banks or FACTS devices.
Protection Relay
The intelligent device that detects faults from CT/VT signals and trips breakers — modern units are IEC 61850 IEDs.
R
Reactive Power
Power that oscillates between source and load sustaining electric and magnetic fields — controls system voltage.
S
Sag
The vertical drop of a conductor below its attachment points — increases with temperature, governs ground clearance.
SCADA
Supervisory Control And Data Acquisition — the system operators use to monitor and control substations remotely.
SF6
Sulfur hexafluoride — the insulating and arc-quenching gas used in GIS and many HV breakers.
Shield Wire
The grounded wire strung at the top of towers to intercept lightning strikes before they hit phase conductors.
Single Line Diagram
The standard one-line schematic representing a three-phase power system — the master drawing of every substation.
Span
The horizontal distance between two adjacent towers — typically 350–450 m on 400 kV lines.
Stringing
The construction operation of pulling conductors and shield wires onto erected towers under controlled tension.
Substation
A facility that switches, transforms and protects power flow between parts of the grid.
Suspension Tower
The standard tangent tower that simply carries conductors on vertical insulator strings — the majority of any line.
Switchyard
The outdoor equipment area of a substation — gantries, breakers, disconnectors and instrument transformers.
T
Tap Changer
See OLTC — the voltage-regulation mechanism of a transformer.
Turnkey
A delivery model where the contractor hands over a fully commissioned, ready-to-operate facility.
V
VT
Voltage Transformer — an instrument transformer that scales primary voltage down for metering and protection.